fuel pump RENAULT TWINGO 2009 2.G Electrical Equipment - Petrol Injection Workshop Manual

Page 11 of 348

17B-11V7 MR-413-X44-17B000$030.mif
PETROL INJECTION
Fault finding – System operation17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
Engine immobiliser
The SIM 32 computer manages an engine immobiliser program:
–The Verlog 4 type immobiliser function is managed by the UCH computer and the engine management computer.
Before any customer request, the engine management computer and UCH exchange authentication frames via the
multiplex network to determine whether or not to start the engine.
After more than five consecutive failed authentication attempts, the engine management computer goes into
protection (antiscanning) mode and no longer tries to authenticate the UCH. It only leaves this mode when the
following sequence of operations is carried out:
–the ignition is left on for at least 60 seconds,
–the signal is cut off,
–the injection computer self-supply cuts out when it should (the time varies according to engine temperature).
After this, only one authentication attempt is allowed. If this fails again, repeat the sequence of operations described
above.
If the engine management computer still fails to unlock, contact the Techline.
Impact detected
If an impacthas been stored by the injection computer (ET077 Impactdetected), switch off the ignition for10 seconds,
thenswitch it back on so that the e ngine can b e started. Then clear the faults using commandRZ0 01 Fault memory.
Fuel supply
Fuel is supplied by the fuel pump. It is controlled each time the ignition is switched on, for 1 second, to provide a
certain pressure level in the circuit, and thereby achieve correct engine starting, particularly if the vehicle has not
been used for a long time. When the engine is running, the fuel pump relay is always controlled.
Injection
The injectors are controlled according to several modes. The engine is started in "semi-full group" mode (injectors
1 and 4, then injectors 2 and 3 simultaneously). This is to ensure correct engine starting whether or not it is correctly
phased, then it enters sequential mode.
It can sometimes, though rarely, happen that the engine starts when incorrectly phased. Then, after it has changed
to sequential injection mode and as long as the cylinder 1 recognition program has not taken place, the injectors are
offset by two cylinders: injection occurs in 4-2-1-3 order instead of the expected 1-3-4-2.
Injection timing is continuously calculated. It can be zero in the event of cut-off whilst decelerating or overrevving for
example.
Engine phasing
SIM 32 D4F 764 injection systems are equipped with a delayed continuous inlet camshaft dephaser.
The injection receives the position of the camshaft dephaser given by the camshaft sensor signal.
This position does not recognise whether the camshaft dephaser is in defect mode or not.
There are two types of defect mode associated with the various types of camshaft dephaser faults:

Page 21 of 348

17B-21V7 MR-413-X44-17B000$050.mif
17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
RV* / LV*: Cruise control/Speed Limiter1 - Injection computer 16 - Upstream sensor signal
2 - RV* / LV* buttons 17 - Ignition command
3 - Multiplex network 18 - Bleed canister command
4 - Turbocharger 19 - Fuel pump command
5 - Motorised throttle 20 - Downstream sensor signal
6 - Manifold pressure 21 - ESP computer
7 - Injector command 22 - Rev counter computer
8 - Clutch Pedal 23 - ABS computer
9 - Brake pedal 24 - Instrument panel computer
10 - Accelerator pedal 25 - Sequential gearbox computer
11 - Refrigerant fluid pressure 26 - AIRBAG computer
12 - Air conditioning compressor command 27 - Vehicle speed sensor computer
13 - Engine cooling fan assembly command 28 - Air conditioning computer
14 - Flywheel signal 29 - UCH computer
15 - Pinking signal 30 – Turbocharging pressure
PETROL INJECTION
Fault finding – Functional diagram

Page 23 of 348

17B-23V7 MR-413-X44-17B000$060.mif
PETROL INJECTION
Fault finding – Features17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
Engine immobiliser
The SIM 32 computer manages an engine immobiliser program:
–The Verlog 4 type immobiliser function is managed by the UCH computer and the engine management computer.
Before any customer request, the engine management computer and UCH exchange authentication frames via the
multiplex network to determine whether or not to start the engine.
After more than five consecutive failed authentication attempts, the engine management computer goes into
protection (antiscanning) mode and no longer tries to authenticate the UCH. The engine management computer only
exits this mode if the following sequence of operations is respected:
–the ignition is left on for at least 60 seconds,
–the signal is cut off,
–the injection computer self-feed deactivates when it should (the time varies according to engine coolant
temperature.
Following this sequence of operations, a single authentication attempt is authorised. If this fails again, repeat the
sequence of operations described above.
If the engine management computer still fails to unlock, contact the Techline.
Impact detected
If an impact has been stored by the injection computer (ET077 Impact detected), switch off the ignition for
10 seconds, then switch it back on so that the engine can be started. Then clear the faults using command RZ001
Fault memory.
Fuel supply
Fuel is supplied by the fuel pump. It is controlled each time the ignition is switched on, for 1 second, to provide a
certain pressure level in the circuit, and thereby achieve correct engine starting, particularly if the vehicle has not
been used for a long time. When the engine is running, the fuel pump relay is always controlled.
Injection
The injectors are controlled according to several modes. In particular, the engine is started in semi-full group mode
(injectors 1 and 4, then injectors 2 and 3 simultaneously), to ensure a correct start whether or not it is correctly
phased, then it enters sequential mode.
It can sometimes, though rarely, happen that the engine starts when incorrectly phased.
Then, after it has changed to sequential injection mode and as long as the cylinder 1 recognition program has not
taken place, the injectors are offset by two cylinders: injection occurs in the order 4-2-1-3 instead of the expected
order 1-3-4-2.
Injection timing is continuously calculated. It can be zero in the event of cut-off whilst decelerating or overrevving for
example.

Page 40 of 348

17B-40V7 MR-413-X44-17B000$120.mif
17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
Tool faultAssociated
DTCDiagnostic tool title
DF001115Coolant temperature sensor circuit
DF002110Air temperature sensor circuit
DF004235Turbocharger pressure sensor circuit (Vdiag 54 only)
DF011641Sensor supply voltage no. 1
DF012651Sensor feed voltage no. 2
DF026201Cylinder 1 injector control circuit
DF027202Cylinder 2 injector control circuit
DF028203Cylinder 3 injector control circuit
DF029204Cylinder 4 injector control circuit
DF038606Computer
DF046560Battery voltage
DF054243Turbocharger solenoid valve control circuit (Vdiag 54 only)
DF059301Misfiring on cylinder 1
DF060302Misfiring on cylinder 2
DF061303Misfiring on cylinder 3
DF062304Misfiring on cylinder 4
DF079638Motorised throttle valve automatic control
DF08010Camshaft dephaser circuit (Vdiag 4C/50 only)
DF081443Canister bleed solenoid valve circuit
DF082135Upstream oxygen sensor heating circuit
DF083141Downstream oxygen sensor heating circuit
DF084685Actuator relay control circuit
DF085627Fuel pump relay control circuit
PETROL INJECTION
Fault finding – Fault summary table

Page 69 of 348

17B-69V7 MR-413-X44-17B000$131.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF059
PRESENT
OR
STOREDCOMBUSTION MISFIRES ON CYLINDER 1
1.DEF: Destructive misfiring
2.DEF: Polluting misfiring
3.DEF: EOBD
NOTESPriorities when dealing with a number of faults:
Firstly, deal with the following faults:
–ignition:
–DF361 Ignition coil circuit 1-4,
–DF362 Ignition coil circuit 2-3
–fuel supply circuit:
–DF026 Cylinder 1 injector circuit
–DF027 Cylinder 2 injector circuit,
–DF028 Cylinder 3 injector circuit
–DF029 Cylinder 4 injector circuit,
–DF085 Fuel pump relay control circuit,
–engine flywheel signal faults:
–DF154 Flywheel signal sensor circuit,
–DF457 Engine flywheel target.
Conditions for applying the fault finding procedure to stored faults:
The fault is considered present when the engine is running.
Special notes:
1.DEF: As soon as the fault is detected, the injection is cut for the faulty cylinder(s) to
limit the rise in temperature inside the catalytic converter. The OBD warning light
flashes for as long as the fault is present.
2.DEF and 3.DEF: The OBD warning light is permanently illuminated.
Misfiring on
cylinder 1 only
The fault is probably due to a component that can only affect this cylinder:
–check the valve clearance,
–check the cylinder 1 injector,
–check the condition and the conformity of the spark plug for cylinder 1,
–measure the compression of cylinder 1.
SIM32_V44_DF059/SIM32_V4C_DF059/SIM32_V50_DF059/SIM32_V54_DF059
AFTER REPAIREnsure that all the faults have been dealt with.
Clear the stored faults. Do not clear the programming.
To check that the system has been properly repaired:
- there must be no further electrical faults,
- programming has been carried out,
- the engine should be warm (minimum temperature 75˚C)
Run the engine at idle speed with all electrical consumers drawing power for 15 minutes.

Page 72 of 348

17B-72V7 MR-413-X44-17B000$131.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF060
PRESENT
OR
STOREDMISFIRING ON CYLINDER 2
1.DEF: Destructive misfiring
2.DEF: Polluting misfiring
3.DEF: EOBD
NOTESPriorities when dealing with a number of faults:
Firstly, deal with the following faults:
–ignition:
–DF361 Ignition coil circuit 1-4,
–DF362 Ignition coil circuit 2-3
–fuel supply circuit:
–DF026 Cylinder 1 injector circuit
–DF027 Cylinder 2 injector circuit,
–DF028 Cylinder 3 injector circuit
–DF029 Cylinder 4 injector circuit,
–DF085 Fuel pump relay control circuit,
–engine flywheel signal faults:
–DF154 Flywheel signal sensor circuit,
–DF457 Engine flywheel target.
Conditions for applying the fault finding procedure to stored faults.
The fault is declared present with the engine running.
Special notes:
1.DEF: As soon as the fault is detected, the injection is cut for the faulty cylinder(s) to
limit the rise in temperature inside the catalytic converter. The OBD warning light
flashes for as long as the fault is present.
2.DEF and 3.DEF: The OBD warning light is permanently illuminated.
Misfiring on
cylinder 1 only
The fault is probably due to a component that can only affect this cylinder:
–check the valve clearance,
–check the cylinder 1 injector,
–check the condition and the conformity of the spark plug for cylinder 1,
–measure the compression of cylinder 1.
SIM32_V44_DF060/SIM32_V4C_DF060/SIM32_V50_DF060/SIM32_V54_DF060
AFTER REPAIREnsure that all the faults have been dealt with.
Clear the stored faults. Do not clear the programming.
To check that the system has been properly repaired:
- there must be no further electrical faults,
- programming has been carried out,
- the engine should be warm (minimum temperature 75˚C)
Run the engine at idle speed with all electrical consumers drawing power for 15 minutes.

Page 75 of 348

17B-75V7 MR-413-X44-17B000$131.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF061
PRESENT
OR
STOREDMISFIRING ON CYLINDER 3
1.DEF: Destructive misfiring
2.DEF: Polluting misfiring
3.DEF: EOBD
NOTESPriorities when dealing with a number of faults:
Firstly, deal with the following faults:
–ignition:
–DF361 Ignition coil circuit 1-4,
–DF362 Ignition coil circuit 2-3
–fuel supply circuit:
–DF026 Cylinder 1 injector circuit
–DF027 Cylinder 2 injector circuit,
–DF028 Cylinder 3 injector circuit
–DF029 Cylinder 4 injector circuit,
–DF085 Fuel pump relay control circuit,
–engine flywheel signal faults:
–DF154 Flywheel signal sensor circuit,
–DF457 Engine flywheel target.
Conditions for applying the fault finding procedure to stored faults.
The fault is declared present with the engine running.
Special notes
1.DEF: As soon as the fault is detected, the injection is cut for the faulty cylinder(s) to
limit the rise in temperature inside the catalytic converter. The OBD warning light flashes
for as long as the fault is present.
2.DEF and 3.DEF: The OBD warning light is permanently illuminated.
Misfiring on
cylinder 3 only
The fault is probably due to a component that can only affect this cylinder:
–check the valve clearance,
–check the cylinder 3 injector,
–check the condition and the conformity of the spark plug for cylinder 3,
–measure the compression of cylinder 3.
SIM32_V44_DF061/SIM32_V4C_DF061/SIM32_V50_DF061/SIM32_V54_DF061
AFTER REPAIREnsure that all the faults have been dealt with.
Clear the stored faults. Do not clear the programming.
To check that the system has been properly repaired:
- there must be no further electrical faults,
- programming has been carried out,
- the engine should be warm (minimum temperature 75˚C)
Run the engine at idle speed with all electrical consumers drawing power for 15 minutes.

Page 78 of 348

17B-78V7 MR-413-X44-17B000$131.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF062
PRESENT
OR
STOREDMISFIRING ON CYLINDER 4
1.DEF: Destructive misfiring
2.DEF: Polluting misfiring
3.DEF: EOBD
NOTESPriorities when dealing with a number of faults:
Firstly, deal with the following faults:
–ignition:
–DF361 Ignition coil circuit 1-4,
–DF362 Ignition coil circuit 2-3
–fuel supply circuit:
–DF026 Cylinder 1 injector circuit
–DF027 Cylinder 2 injector circuit,
–DF028 Cylinder 3 injector circuit
–DF029 Cylinder 4 injector circuit,
–DF085 Fuel pump relay control circuit,
–engine flywheel signal faults:
–DF154 Flywheel signal sensor circuit,
–DF457 Engine flywheel target.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present with the engine running.
Special notes:
1.DEF: As soon as the fault is detected, the injection is cut for the faulty cylinder(s) to
limit the rise in temperature inside the catalytic converter. The OBD warning light
flashes for as long as the fault is present.
2.DEF and 3.DEF: The OBD warning light is permanently illuminated.
Misfiring on
cylinder 4 only
The fault is probably due to a component that can only affect this cylinder:
–check the valve clearance,
–check the cylinder 4 injector,
–check the condition and conformity of the cylinder 4 spark plug,
–measure the compression of cylinder 4.
SIM32_V44_DF062/SIM32_V4C_DF062/SIM32_V50_DF062/SIM32_V54_DF062
AFTER REPAIREnsure that all the faults have been dealt with.
Clear the stored faults. Do not clear the programming.
To check that the system has been properly repaired:
- there must be no further electrical faults,
- programming has been carried out,
- the engine should be warm (minimum temperature 75˚C)
Run the engine at idle speed with all electrical consumers drawing power for 15 minutes.

Page 99 of 348

17B-99V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF085
PRESENT
OR
STOREDFUEL PUMP RELAY CONTROL CIRCUITCO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: EOBD
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present with the ignition on or the engine running, or during
command AC015 Fuel pump relay.
Special notes:
CO/CC.1: The effect of the fault is the same as running out of fuel. The vehicle stalls
and cannot be restarted.
CC.0: There is danger of fire in the event of petrol leaking during an accident.
Intermittent CO: Risk of intermittent ignition cut-off and draining the battery.
Use the Wiring Diagrams Technical Note for NEW TWINGO, E33, CLIO III,
or MODUS.
Check the condition of the engine management computer connector (component code 120).
If the connector is faulty and there is a repair method (see Technical Note 6015A, Repairing electrical wiring,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
For NEW TWINGO or E33:
Check the condition of the fuel pump relay (component code 236).
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Use the "universal bornier" to check the insulation and continuity of the following connection:
●3AC between components 236 and 120,
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for an earth during activation of command AC015 Fuel pump relay.
SIM32_V44_DF085/SIM32_V4C_DF085/SIM32_V50_DF085/SIM32_V54_DF085
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.

Page 100 of 348

17B-100V7 MR-413-X44-17B000$132.mif
PETROL INJECTION
Fault finding – Interpretation of faults17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
DF085
CONTINUED
With the ignition on, if the + 12 V is still not present on the fuel pump relay connector, there is a fault in the engine
fuse and relay box.
Run fault finding on the engine fuse and relay box to check the continuity of the following connection:
●BP17 between components 120 and 597,
●BP17 between components 1033 and 597.
If the connection is faulty and if there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, check the battery and run fault finding on the charging circuit (see Technical Note 6014A,
Checking the charging circuit).
For CLIO III or MODUS:
Check the condition of the Protection and Switching Unit (see Wiring Diagram Technical Note, CLIO III or
MODUS, component code 1337).
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Use the "universal bornier" to check the insulation and continuity of the following connection:
●3AC between components 1337 and 120.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for an earth during activation of command AC015 Fuel pump relay.
If the fault is still present, there is a fault in the Protection and Switching Unit (the fuel pump relay is in the Protection
and Switching Unit and cannot be dismantled).
Run fault finding on the UPC, component code 1337 (see 87G, Engine compartment connection unit).
If the fault is still present, contact the Techline.
AFTER REPAIRFollow the instructions to confirm repair:
- If the fault is present, continue to deal with the fault.
- If the fault is stored, ignore it.
Deal with any other faults.
Clear the stored faults.

Page:   1-10 11-20 21-30 next >